  • Stainless Steel
  • Zing Ear Ceiling Fan Switch 3 speed 4 wire pull chain replacment: Model ZE-268S6.
  • 3 Speed control: high, medium, low ; Function: off, L-1, L-2-3, L-3
  • Ceiling Fan Parts Certifications: UL approved (USA) - CSA certified (Canada).
  • ZE-268S6 Ceiling Fan Switch Electrical Rating: 6A/125VAC - 3A/250VAC.
  • Perfect for home applications such as Ceiling Fans, Wall Lamps, Cabinet Light. Works in Hunter, Casablanca, Harbor Breeze, Hampton Bay and so on

$ 12,91 12.91 USD $ 12,91

Not Available For Sale

($ 12,91 / Units)
10 people are viewing this right now

  • Produttore
  • Conteggio unità
  • Dimensioni articolo L x W x H
  • Metodo di controllo
  • Specificazione Met
  • Tipo di comando
  • Materiale di contatto
  • Tipo di contatto
  • Valutazione attuale
  • Tensione di funzionamento
  • Terminal
  • Tipo di circuito
  • Tipo di attuatore
  • Marca
  • UPC
  • Tipo di controllo
  • Numero di articoli
  • Modalità di funzionamento
  • Dispositivi compatibili
  • Potenza
  • Materiale
  • Colore
  • Tipo di connettore
  • Tipo di montaggio
  • Articolo Peso
  • Tipo di interruttore
  • Numero della parte
  • Modello
  • Tipo di materiale
  • Valutazione della protezione internazionale
  • Numero di posizioni
  • Protocollo di connettività
  • Dimensioni articolo
  • Tipo di prodotto

Questa combinazione non esiste.

catena tirante

Termini e condizioni
Garanzia di rimborso di 30 giorni
Spedizione: 2-3 giorni lavorativi

Estimated shipping
Select a product to estimate shipping.

Important information

Please disconnect the power to the fan before removing the old switch.

This 3-speed 4 wire fan switch fits many ceiling fans including Hunter, Harbor Breeze, Hampton Bay, Casablanca, Westinghouse, Emerson, and Kichler.

Attention: Before rewiring any ceiling fan. Turn off electrical current at source by turning off circuit breakers.

Steps:

1. Write down the color of each wire and the portal number to which they are attached on the switch

2. Remove wires from the existing fan switch If wires are hard to remove, insert a paper clip or a large sewing needle into each hole (numbered 1, 2, 3, L)and pull the wire out (repeat this step for each wire)

3. Make sure that the Wire lead length is the same length as the line beside the word "STRIP"

4. Insert wires into the new switch as in the previous switch(see step 1) Wires should be inserted into the slots on side of the switch not the holes on the surface

Color Codes For Ceiling Fans( Your Fan Wires Color &Position May Vary)

Harbor Breeze ceiling fan: L=Black, 2=Brown, 1=Gray, 3=Purple OR L=Black, 2=Gray, 1=Brown, 3=Purple

Harbor Breeze ceiling fan-alternate colors: L=Black, 2=Pink, 1=Yellow, 3=Gray

Hampton Bay ceiling fan: L=Black, 2=Brown, 1=Purple, 3=Gray OR L=Black, 2=Brown, 1=Gray, 3=Purple

Hampton Bay ceiling fan -Alternate colors: L=Black, 2=Purple, 1=Red, 3=Yellow

Hunter ceiling fan: L=Black, 2=Brown, 1=Gray, 3=Green

Monte Carlo ceiling fan: L=Back, 2=Brown, 1=White, 3=Purple

What situation you should replace your ceiling fan pull switch?

A. Your ceiling fan pull switch doesn't work

B. Internal ceiling fan chain break.

When no ceiling fan chain is visible, this likely means that the pull within the ceiling fan has broken near or inside the ceiling fan pull switch. In that case, proceed to replace.

Equipment & Tools

6-foot step ladder

Voltage tester

Wire stripper

Manual screwdriver

Pliers (if needed)

Soft rag (if needed)

Pull chain extender or pull chain switch kit

Electrical wire nuts

Remove the Metal Collar

Unscrew the metal collar through which the ceiling fan chain should extend. First try screwing off the collar with your fingers, turning counterclockwise. If this does not work, use pliers and a soft rag wrapped around the metal collar to protect the collar and the fan housing from damage.

Open the Fan Base

Remove any light bulbs from the ceiling fan. With a manual screwdriver, turn out the screws holding the removable lower section from the ceiling fan motor base. Set the screws aside. Gently pull off the removable section. Leave it attached by its wires to the ceiling fan base.

Pull out the Pull Chain Switch

Locate the ceiling fan chain switch. It should be a small plastic unit, often with a transparent side or green one. You may even be able to see the broken pull within the switch unit. Carefully pull this down. It will be usually attached to the fan with three or four wires.

WARNING: Do not attempt to fix the pull chain switch. Instead, it is easier and safer to discard the old switch and replace it with a new switch. Ceiling fan pull switch kits are inexpensive and readily available online.

Cut the Wires to the Fan Chain Switch

With the wire stripper, use the cutting section to snip off the three or four wires that attach the ceiling fan chain switch to the ceiling fan base. Leave at least 2 inches of wire attached to the ceiling fan base to make it easier to reattach the new pull chain switch.

Attach the New Pull Switch to the Ceiling Fan

After stripping the plastic from the wires to expose the copper wire, attach the three or four wires of the new ceiling fan chain pull switch to the fan's wires. Twist together the wires. Top off each connection with a plastic wire nut.

Tips: Be very careful to match the wiring of the old switch with the wiring of the new switch.

Thread the Pull Chain Through the Hole

Gently press the pull chain switch back into the ceiling fan base. Thread the pull chain through the hole in the housing.

Reassemble and Test the Ceiling Fan

Tighten the metal collar by hand. Reattach the lower section of the ceiling fan. Add any light bulbs. Turn the power back on at the circuit breaker and any wall switches. Test the fan by carefully pulling on the ceiling fan pull.

Product details

Ceiling Fan Pull Chain Switch - 3 Speed Replacement -14
Ceiling Fan Pull Chain Switch - 3 Speed Replacement -15
Ceiling Fan Pull Chain Switch - 3 Speed Replacement -16
Ceiling Fan Pull Chain Switch - 3 Speed Replacement -17
Ceiling Fan Pull Chain Switch - 3 Speed Replacement -18
Ceiling Fan Pull Chain Switch - 3 Speed Replacement -19
Ceiling Fan Pull Chain Switch - 3 Speed Replacement -20
Ceiling Fan Pull Chain Switch - 3 Speed Replacement -21
Ceiling Fan Pull Chain Switch - 3 Speed Replacement -22
Ceiling Fan Pull Chain Switch - 3 Speed Replacement -23
Ceiling Fan Pull Chain Switch - 3 Speed Replacement -24
Main Specification
Specificazione Met CSA or Ul_listed
Dispositivi compatibili Ceiling Fans or Wall Lamps or Cabinet Lights or Hunter or Casablanca or Harbor Breeze or Hampton Bay
Produttore DAYONE
Conteggio unità 1 conteggio
Dimensioni articolo L x W x H 1.97 x 1.18 x 0.59 inches
Metodo di controllo App
Tipo di comando Manual Pull Chain
Materiale di contatto Nickel
Tipo di contatto Make
Valutazione attuale 6 A
Tensione di funzionamento 250 Volt
Terminal Attraverso il foro
Tipo di circuito 3-way
Tipo di attuatore Rotary
Marca DAYONE
UPC 703064554037
Tipo di controllo Speed Control
Numero di articoli 1
Modalità di funzionamento Fuori
Potenza 750 watt
Materiale Plastica
Colore ZE-268S6 Nickel 1Pack
Tipo di connettore Cripta
Tipo di montaggio Embedded
Articolo Peso 8 g
Product information
Tipo di interruttore Pull Chain Speed Switch
Technical Details
Numero della parte ZEAM2800
Modello ZEAM2800
Tipo di materiale Plastica
Valutazione della protezione internazionale 125
Numero di posizioni 4
Protocollo di connettività Electrical Wire
Measurements
Dimensioni articolo 1.97 x 1.18 x 0.59 inches
Others
Tipo di prodotto Tirare le catene